TM 9-4110-255-14
4-43. FLANGE BEARING (CONDENSER FAN) REPLACEMENT .
This task covers:
a. Removal
b. Installation
INITIAL SETUP
Materials/Parts:
General Safety Instructions:
Lock Washers (4)
WARNING
Equipment Conditions:
Exposed rotating parts are used in the
refrigeration unit. Personal injury can result if
Refrigeration unit shut down (para 2-7) and battery
battery is connected.
a. Removal.
(1) Remove four bolts (1), lock washers (2), and bracket (3). Discard lock washers.
(2) Loosen two set screws (4).
(3) Slide flange bearing (5) off fan drive shaft (6).
NOTE
A new flange bearing is supplied with a straight lubrication fitting that must be replaced with a
900 fitting.
(4) Remove lubrication fitting (7) and retain for use during installation.
4-107