TM 9-4110-255-14
4-45. GREASE FITTING EXTENSION REPLACEMENT .
This task covers:
a. Removal
b. Installation
INITIAL SETUP
Materials/Parts:
General Safety Instructions:
Self Locking Nut
WARNING
Equipment Conditions:
Exposed rotating parts are used in the
Refrigeration unit shut down para 2-7) and battery
refrigeration unit. Personal injury can result if
battery is connected.
Right side door open.
a. Removal.
NOTE
Grease fitting is not supplied with grease fitting extension.
(1) Remove grease fitting (1) and retain for use during installation.
(2) Remove self locking nut (2), bolt (3), and clamp (4). Discard self locking nut.
(3) Remove two grommets (5).
(4) Pull grease fitting extension (6) through enclosure then remove.
Figure 4-39. Grease Fitting Extension
4-110