4-47. SOLENOID VALVE L1 (LIQUID LINE) TESTING AND REPAIR.
This task covers:
a. Testing
b. Removal
c. Installation.
INITIAL SETUP
Materials/Parts:
General Safety Instructions:
Marker tags (2)
WARNING
Exposed rotating parts are used in the
Equipment Conditions:
refrigeration unit. Personal injury can result if
battery is connected.
Refrigeration unit shut down (para 2-7) and battery
Left side door open.
a. Testing.
(1) Tag and disconnect tabs (1).
(2) Using multimeter set to measure continuity, check coil (2) continuity between tabs (1). Continuity should
be indicated. If no continuity was indicated, replace coil.
(3) Using multimeter set to measure continuity, check coil (2) continuity between each tab (1) and coil (2)
metal case. No continuity should be indicated. If continuity was indicated, replace coil.