TM 9-4110-255-14
5-29. ACCUMULATOR REPLACEMENT .
This task covers:
a. Removal
b. Installation
INITIAL SETUP
Equipment Conditions:
Materials/Parts:
Self Locking Nut
Self Locking Nut
Left side door open.
Insulation Tape
a. Removal.
(1) Remove insulation (1) as necessary.
NOTE
Note flow direction prior to debrazing fittings.
(3) Remove self locking nut (3), and flat washer (4). Discard self locking nut.
(4) Remove self locking nut (5), flat washer (6), bolt (7), flat washer (8), and accumulator (9).
b. Installation.
(2) Install accumulator (9), flat washer (8), bolt (7), flat washer (6), and new self locking nut (5).
(3) Install flat washer (4) and new self locking nut (3).
NOTE
Be sure to observe flow direction noted prior to debrazing.
(5) Install insulation (1) and secure with insulation tape as necessary.
5-51