TM 9-4110-258-13
5.40
This task covers:
a. Repair
INITIAL SETUP
Equipment Conditions:
General Safety Instructions:
WARNING
disconnected.
High voltage and rotating parts are used in
the refrigeration unit. Personal injury can
result if power is connected.
Repair.
(1) Disassemble refrigeration unit as necessary and make repairs as indicated.
(2) Drill through rivet or blind rivet nut using drill bit slightly smaller than rivet diameter.
(3) Remove any remaining rivet material.
(4) Install new rivet or blind rivet nut as required.
(5) Repair any minor sheet metal dents and bent edges by straightening using common sheet metal repair
procedures.
(6) Weld any cracks or breaks in frame members or welds per MIL-B-7883.
(7) Touch-up any painted surfaces per TM 43-0139.
(8) Assemble refrigeration unit as necessary to return to service.
5-82