TM 9-4110-258-13
.
5.42 DOORS/COVER REPAIR AND REPLACEMENT
This task covers:
a. Repair
b. Removal
c. Installation
INITIAL SETUP
Equipment Conditions:
General Safety Instructions:
WARNING
disconnected.
High voltage and rotating parts are used in
the refrigeration unit. Personal injury can
result if power is connected.
a. Repair.
(1) If hinge is damaged, drill through rivets using drill bit slightly smaller than rivet diameter.
Remove
door/cover and hinge.
(2) Remove any remaining rivet material.
(3) Install new hinge, door/cover and rivets as necessary.
(4) Repair any minor sheet metal dents and bent edges by straightening using common sheet metal repair
procedures.
(5) Weld any cracks or breaks in doors/cover per MIL-B-7883.
(6) Touch-up any painted surfaces per TM 43-0139.
b. Removal.
(1) Drill through rivets securing doors/cover to hinge using drill bit slightly smaller than rivet diameter.
(2) Remove doors/cover and any remaining rivet material.
c. Installation. Install new door/cover and secure to hinge with rivets as necessary.
5-84