TM 9-4120-370-14
TO 35E9-229-1
5-27. LIQUID QUENCH EXPANSION VALVE - Continued.
(8) Leak test all newly connected joints and those in the repaired area. (See para 5-10.)
Follow-on procedure:
5-28. RECEIVER
Preliminary procedure:
a.
Inspection
(1) Check for general condition and signs of leakage, If leakage is suspected, leak test per paragraph 5-10.
(2) Check that mounting hardware is secure.
b . Removal
(1) Discharge the refrigeration system in accordance with paragraph 5-7.
(2) Using screwdriver, remove two screws, flat washers, nuts, and clamps from receiver.
(3) Purge the system with nitrogen and debraze the tube connections. (See para 5-8 and para 5-9.)
(4) Remove the receiver.
Installation
c.
(1) Place the receiver on the tube ends, purge the system with nitrogen, and braze the tube joints. (See para
(2) Using a screwdriver and wrench, secure the receiver to the side panel with two screws, flat washers, nuts,
and clamps.
(4) Leak test all newly connected joints and those in the repair area. (See para 5-10.)