TM 9-4120-385-14
5. Remove screw (5) and lockwasher (6) to release each of two bracket.
6. Remove receiver (8) and brackets (4) from casing.
7. Remove screw (1), lockwasher (2), and nut (3) to remove each bracket (4).
INSTALLATION.
c.
1. Slide brackets (4) over receiver (8) and attach with screw (1), lockwasher (2), and
nut (3) on each, but do not tighten.
2. Align brackets (4) with holes in casing and secure each with a screw (5) and
lockwasher (6).
CAUTION
Wrap wet rags around solenoid valves and expansion valve during
debrazing to act as a heat sink and prevent damage to valves.
4. Braze refrigeration tubing to receiver (8).
5. Tighten hardware on each bracket (4) to secure receiver (8).
10. Install junction box and control panel and secure with four captive screws.
11. Install lower panel and tighten panel fasteners.
a.
5-81