1
-
Load dc ammeter
B - Safety clip
2
-
Field dc ammeter
C - Stop button
34 -
Drive running indicator lamp
3
-
Tachometer indicator meter
4
-
Dc volts-millivolts meter
35 -
Pile flutter circuit instrument panel
A - Phone jack
5
-
Dc voltmeter
6
-
Ac ammeter
B - Positive and negative binding posts
36 -
7
-
Ac voltmeter
i n s t r u m e n t panel
8
-
Load dc ammeter calibrating binding posts
9
-
FieId dc ammeter calibrating binding posts
B - Regulator check input binding post
10
-
37
-
0-25 0-12.5 ampere load switch variable control
posts
38
-
0-25 0-12.5 load switch
11
- Dc volts-millivolts meter calibrating binding
posts
39
-
25-12.5 fixed load switch
40
-
50-25 fixed load switch
12
41
-
Battery circuit selector instrument panel
13
- Ac ammeter calibrating jack
A - Voltage selector switch
14
B - Battery on-off switch
15
- Load dc ammeter range selector switch
C - Battery test circuit positive and negative
16
- Load dc ammeter starter test selector switch
binding posts
17
- Field dc ammeter range selector switch
42 -
Rectifier input binding posts
18
- Tachometer indicator high-low switch
A - No. T1 binding post
19
- Tachometer indicator direct-drive-calibrating
B - No. D- binding post
p o t e n t i o m e t e r switch
C - No. T2 binding post
20
- Dc volts-millivolts range selector switch
D - No. C+ binding post
21
- Dc volts-millivolts momentary-on switch
E - No. T3 binding post
22
43
-
Battery charge circuit breaker
23
- Dc voltmeter circuit selector switch
44
-
Battery charge fuse holder
24
- Ac ammeter phase selector switch
45
-
Battery charge indicator lamp
25
- Ac ammeter range selector switch
46
-
Battery charge timer
26
47
-
Battery charge circuit variable c o n t r o l
27
- Ac voltmeter phase selector switch
48
-
Dc variable power supply control
28
- Variable volts circuit instrument panel
49
-
Dc power supply circuit breaker
A - Variable volts on-off switch
50
-
Polarity reversing switch
B - Variable volts circuit fuse holder
51
-
Generator field external-internal ground switch
C - Dc variable volts positive and negative
52
-
40-ohm field current rheostat
b i n d i n g posts
53
-
Field current rheostat-regulator switch
29
- External dc voltmeter positive and negative
54
-
250-ohm 5-amperes maximum switch
binding posts
55
-
250-ohm field current rheostat
30
- Test indicator circuit instrument panel
56
-
250-ohm field current rheostat fuse holder
A - Test indicator lamp
57
-
100-50 fixed load switches
B - Positive and negative binding posts
58
-
Tachometer indicator calibrating potentiometer
31
- Ac power-on indicator lamp
59
-
Field ammeter dc ac/dc switch
32
- Speed control
60
-
Battery charge rate read switch
33
- Drive control
61
-
Starter test load disconnect switch
A - Start button
OPERATION UNDER USUAL CONDITIONS
Section Ill.
91. Preparation for Operation
a. A d j u s t e a c h o f t h e s e v e n m e t e r s ( 1
This section contains instructions for the
through 7, fig. 16) to zero, if required, by turn-
operation of the test stand under conditions of
i n g the adjustment screw (located below lens
moderate temperature and humidity. Every or-
on center part of meter) clockwise to swing the
ganization equipped with this item must thor-
p o i n t e r to the right, or counterclockwise to
oughly train its personnel in the procedures for
swing the pointer to the left.
o p e r a t i n g this item. For operation under un-
cuitry for a direct-driven generator (97b) and
through 106.