Table 3-11. DMS-D Performance Test-Continued
Table 3-11. DMS-D Performance Test-Continued
STEP
UNIT
PROCEDURE
CORRECTIVE ACTION
STEP
UNIT
PROCEDURE
CORRECTIVE ACTION
1608
TP
Observe GO lamp illuminated and NO GO lamp extinguished.
1629
VWS
Adjust AMPTD(VOLTS) control to +0.952 0.0002 Vdc.
0
1609
VWS
Adjust AMPTD(VOLTS) control to +6.96 0.001 Vdc.
0
DMM
DMM
1630
TP
Momentarily actuate TEST START switch.
1610
TP
Momentarily actuate TEST START switch.
1631
CIP
Observe INHIB lamp illuminated before continuing.
1611
CIP
Observe INHIB lamp illuminated before continuing.
1632
TP
Observe GO lamp extinguished and NO GO lamp illuminated.
1612
TP
Observe GO lamp extinguished and NO GO lamp illuminated.
1633
CIP
COUNTER INHIBIT(SEC) dial to 10.11.
1613
CIP
COUNTER INHIBIT(SEC) dial to 01.91.
1634
MCP
DMM INPUT switch to SEL A,
1614
MCP
DMM INPUT switch to SEL A.
1635
MCP
Adjust COMPARATOR THRESHOLD B control to -0.4060 0.0020 Vdc.
1615
MCP
Adjust COMPARATOR THRESHOLD B conor to -0.9920 0.0020 Vdc.
tl
DMM
DMM
1636
MCP
DMM INPUT switch to DMM INPUT.
1616
MCP
DMM INPUT switch to DMM INPUT.
1637
VWS
+DC/PULSE/-DC switch to +DC.
1617
VWS
Adjust AMPTD(VOLTS) control to +1.01 0.001 Vdc.
2
1638
VWS
Adjust AMPTD(VOLTS) control to +0.479 0.0002 Vdc.
1
DMM
DMM
1618
TP
Momentarily actuate TEST START switch.
1639
TP
Momentarily actuate TEST START switch.
1619
CIP
Observe INHIB lamp illuminated before continuing.
1640
CIP
Observe INHIB lamp illuminated before continuing.
1620
TP
Observe GO and NO GO lamps illuminated.
1641
TP
Observe GO and NO GO lamps illuminated.
1621
VWS
Adjust AMPTD(VOLTS) control to +1.03 0.001 Vdc.
2
1642
VWS
Adjust AMPTD(VOLTS) control to +0.487 0.0002 Vdc.
2
DMM
DMM
1622
TP
Momentarily actuate TEST START switch.
1643
TP
Momentarily actuate TEST START switch.
1623
CIP
Observe INHIB lamp illuminated before continuing.
1644
CIP
Observe INHIB lamp illuminated before continuing.
1624
TP
Observe GO lamp extinguished and NO GO mp illuminated.
la
1645
TP
Observe GO lamp extinguished and NO GO lamp illuminated.
1625
VWS
Adjust AMPTD(VOLTS) control to +0.972 0.0002 Vdc.
0
1646
VWS
Adjust AMPTD(VOLTS) control to +0.332 0.0002 Vdc,
9
DMM
DMM
1626
TP
Momentarily actuate TEST START switch.
1647
TP
Momentarily actuate TEST START switch.
1627
CIP
Observe INHIB lamp illuminated before continuing.
1648
CIP
Observe INHIB lamp illuminated before continuing.
1628
TP
Observe GO and NO GO lamps illuminated,
1649
TP
Observe GO and NO GO lamps illuminated.
3-134