TM 9-2330-227-14&P
LIGHT SWITCHES, 24-AND 110-VOLT
This task covers:
INITIAL SETUP
Personnel Required
Tools
One
Pliers, long round-nose
Screwdriver, cross-tip, number two
Screwdriver, flat-tip, 3/16-inch
ACTION
ITEM
REMARKS
LOCATION
WARNING
Contact with live 110-volt electrical wires could result in serious injury or death. Make
sure power source is disconnected before performing maintenance on the electrical
system.
NOTE
Tag wires to aid in installation (page 4-4). All light switches are removed and installed
the same way. This task is for one; repeat for the others.
REMOVAL
1. Plate (1)
Two screws (2)
Using 3/16-inch flat-tip screwdriver,
unscrew and take off.
4-35