TM 9-2330-356-14
(e) Install new meter or gage in reverse
order of steps (a) through (c).
NOTE
(f) Cleanup all fuel spills.
Put suitable container under tube connec-
tions to catch fuel.
(a) Tag and disconnect electrical leads
connector in hourmeter line.
rear of voltmeter, and/or tube connector (fig. 4-40) from
rear of pump pressure gage.
(b) Remove three screws and nuts from
hourmeter and pull meter out from front of control panel.
(b) Remove two nuts and brackets that
(c) Remove two nuts and bracket that
retain meter or gage to control panel.
retains tachometer to control panel and pull meter out
from front of panel.
(c) Remove meter or gage from panel.
(d) Install new meter in reverse order of
(d) Remove snubber from pump pressure
steps (a) and (b), being careful to reconnect leads exactly
gage.
as they were connected to the meter that was removed.
TA099795