The solvent's flash point is 100F-138F
(c) Remove angle valve and check valve as a
(38C-59C). If you become dizzy while
complete assembly.
using cleaning solvent, immediately get fresh
air and medical help. If solvent contacts eyes,
(d) Separate check valve and angle valve on
immediately wash your eyes with water and
a bench by removing four capscrews, washers, and nuts.
get medical aid.
WARNING
(2) Cleaning and Inspection. Clean with dry
Dry cleaning solvent P-D-680 is toxic and
and valves.
flammable. Always wear protective goggles
(3) Installation. Install valve and new gaskets with
and gloves, and use only in a well-ventilated
sixteen capserews, washers, and nuts. Tighten nuts to
area. Avoid contact with skin, eyes, and
25-35 lb.-ft.
clothes, and DO NOT breathe vapors. DO
NOT use near open flame or excessive heat.
The solvent's flash point is 100F-138F
(38C-59C). If you become dizzy while
using cleaning solvent, immediately get fresh
air and medical help. If solvent contacts eyes,
immediately wash your eyes with water and
get medical aid.
(2) Cleaning and Inspection. Clean with dry
and valves.
(3) Installation.
(a) Assemble angle valve, new gasket, and
check valve assembly by securing both valves together with
four capscrews, washers, and nuts.
(b) Position angle valve and check valve
between manifold and pipe. Install new gasket, four
capscrews, washers, and nuts to secure angle valve to
TA099862
manifold. Do not tighten capscrews.
and M969A1).
Tighten coupling nuts to 57-63 lb.-ft.
f.
4-Inch Control Valve (Bottom Loading)
(d) Tighten capserews securing angle valve
to manifold to 25-35 lb.-ft.
(1) Adjustment (to ensure that fuel shut-off closes).
(a) Start with empty tank.
e.
Check Valve (M967, M967A1, M969, and M969A1)
(b) Refer to flow diagram for either filtered
(1) Removal. Remove sixteen capscrews,
washers, and nuts. Remove valve and gaskets.
(c) Install a 0-60 psi pressure gage in the
WARNING
filtered self-load or non-filtered bottom load.
Dry cleaning solvent P-D-680 is toxic and
(d) Connect underwing nozzle (for
flammable. Always wear protective goggles
self-load) or storage facility hose to the bottom load
and gloves, and use only in a well-ventilated
area. Avoid contact with skin, eyes, and
clothes, and DO NOT breathe vapors. DO
needle valve.
NOT use near open flame or excessive heat.