TM 9-2330-357-14&P
4-52. TORQUE ROD REPLACEMENT (Con't).
b. CLEANING AND INSPECTION
WARNING
Dry cleaning solvent, P-D-680, is toxic and flammable. Always wear protective
goggles and gloves, and use only in a well-ventilated area. Avoid contact with skin,
eyes, and clothes, and DO NOT breathe vapors. DO NOT use near open flame or
excessive heat. The solvent's flash point is 100 -138 (38 -59 ). If you become
F
F
C
C
dizzy while using cleaning solvent, Immediately get fresh air and medical help. If
solvent contacts eyes, immediately wash your eyes and get medical aid.
1. Remove all buildup of grease or dirt by using a clean rag or medium bristle brush and dry cleaning solvent,
and allow to dry.
2. Inspect for loose or damaged rod ends.
3. Inspect all parts for cracks, twists, and burrs.
c. INSTALLATION
1. Install torque rod (3) with two castellated nuts (1). Torque castellated nuts to 350 Ib.-ft. (475 N-m), then
tighten to next slot In nut.
2. Install two new cotter pins (2).
3. Repeat steps 1 and 2 for other five torque rods (3).
FOLLOW-ON TASKS:
Bogie assembly installed by Direct Support Maintenance.
4-109