TM 9-4120-370-14
TO 35E9-229-1
5-14. DEHYDRATOR (FILTER DRIER) - Continued.
Installation
c.
CAUTION
Replacement dehydrators are packed with sealing caps on the flare fittings to
prevent moisture contamination of the desiccant filtering media. Remove these
caps immediately prior to installation. Never install a dehydrator from which caps
have been removed for an extended or unknown period of time.
(1) Place clamp on dehydrator.
(2) Place clamp and dehydrator in unit. Be sure that flow arrow is pointing up.
(3) Using screwdriver, secure clamp with screw, flat washer, and nut.
(4) Using wrench tighten both flare nuts.
(5) Leak test all newly connected pints and those in the repair area. (See para 5-10.)
Followon procedure: Install lower front panel. (See para 4-26.)
5-15. ACTUATING CYLINDERS AND
CONDENSER AIR OUTLET DAMPER LINKAGE (MODELS F36T4-2S,
F36T4-2SA, AND F36T-2S ONLY)
(See para 5-16 for Models F36T-2SA and F36T4-2SB.)
Preliminary procedure:
Remove actuating cylinder access cover. (See para 4-20.)
Access
a.
(1) Using wrench, remove eight cap screws from condenser motor channel support.