TM 9-4120-370-14
T0 35E9-229-1
5-16. ACTUATING CYLINDERS AND
CONDENSER AIR OUTLET DAMPER LINKAGE (MODELS F36T2SA AND
F36T42SB ONLY)
(See para 5-15 for Models F36T4-2S, F36T4-2SA, and F36T-2S.)
Preliminary procedure:
Remove actuating cylinder access cover. (See para 4-20.)
Figure 5-15. Actuating Cylinder for Models F36T-2SA and F36T4-2SB
Inspection
a.
(1) Check actuating cylinder for signs of leakage. If leakage is suspected, leak test per paragraph 5-10.
(2) Check that attaching nuts, linkage connection, and flare nut are in place and secure. Tighten loose parts
and replace if missing.
(3) Check that capillary tubing is not kinked or mashed closed. Replace if damaged.
b . Removal
(2) Using wrench, loosen flare nut and slip away from cylinder flare connection.
(3) Using wrenches, remove the two sets of hardware that consist of four nuts and two cap screws that attach
the connector bracket to the two damper controls.
(4) Using wrench, remove two nuts from actuator mounting studs.
(5) Remove actuating cylinder and connector bracket.