TM 9-4120-378-14
5.20 ACTUATING VYLINDER. - Continued
Location/ltem
Action
Remarks
Removal
- Continued
Installation
a. Install actuating cylinder (4) with studs through
openings in partition. Install two flat washers (6)
and two nuts (5) on studs.
b. Connect the flare nut (3).
c. Insert wire ends (2) into the openings in mechanical
post of actuating cylinder.
Adjustment
a. Extend actuator rod until there is a 1/4 inch (.635
cm) space between inner edge of mechanical post
bracket and the face of the cylinder. Tighten the
screw (1) on the mechanical post.
c. Leak test refrigeration system.
d. Evacuate refrigeration system.
e. Charge refrigeration system.
f. Install top rear and center covers.
5-63