5.20 ACTUATING CYLINDER-INSPECT/ADJUST/REPLACE. This task covers inspect, removal, install and ad-
justment.
INITIAL SETUP
Equipment Conditions:
Remarks
Action
Location/Item
Top of Housing
Avoid bodily contact with liquid refrig-
erant and avoid inhaling refrigerant
gas. Be especially careful that refrig-
erant does not come in contact with
eyes. In case of refrigerant leaks, ven-
tilate area immediately.
Check that power source is discon-
nected. Check that system is dis-
charged of refrigerant.
Inspect
Check for visible damage to cylinder and actuating
wire.
a.
Loosen mechanical post screw (1) to loosen con-
Removal
trol wire in flexible cable (2). Straighten control
wire.
b.
Disconnect flare nut (3) from end of actuating cylin-
der (4).
c.
Remove two nuts (5) and two flat washers (6) from
cylinder (4).