TM 9-2330-356-14
(2) Remove four mounting screws and nuts,
Remove meter.
(3) Flanged nipples on meter inlet and outlet
ports can be removed after meter is removed from
cabinet.
b.
Installation.
(1) Use new gaskets. Install flanged nipples on
outlet ports of meter. Fasten flange to meter with four
50-75 lb.-ft.
(2) Put new gasket over studs on meter inlet port.
Position meter in cabinet and connect to inlet piping with
four self-locking nuts. Tighten nuts to 50-75 lb.-ft. Install
four screws, flatwashers, and self-locking nuts to fasten
meter to cabinet. Tighten to 67-74 Ib.-ft.
2-inch coupling to 57-63 Ib.-ft. Tighten 3-inch coupling to
95-105 lb.-ft.
Deadman Hose Reel (M970 and M970A1)
Outlet Nipple.
a.
Removal.
5-27. Meter Assembly (M970 and M970A1)
(1) Deactivate deadman system per instructions
on plate inside hose reel cabinet.
Removal.
a.
(1) Remove split couplings from nipples on both
sides of meter. Slide the coupling gaskets onto pipe ends
away from the meter. At rear of meter, remove four nuts
(3) Disconnect air lines from ports on both sides
from studs on meter inlet.